page location: home > metal block calibrators > b series metal block calibrators |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Metal Block CalibratorsB Series Metal Block Calibrators
ASL's B series Metal Block Calibrators let you accurately calibrate PRT's and other thermometers easily and conveniently. These rugged, portable blocks provide a very stable and uniform temperature as standard, but you can specify the options to meet your needs precisely. For example, insert options let you use a wide range of probe diameters, saving time and money and, to allow accurate calibration required by IS09000, inserts with two or more holes accept both reference thermometer and the probes to be calibrated. The ASL range of Metal Block Calibrators consists of the B700 for temperatures from +50°C to +700°C and the B140 for temperatures from -25°C to 140°C. To aid rapid cooling from elevated temperatures to ambient ASL has developed the B-Cool forced air cooling probe. Metal Block Calibrators can be supplied with optional independent indicators and RS485 or RS232C interfaces. B700 Metal Block CalibratorThe B700 allows you to accurately calibrate RTDs and other thermometers easily and conveniently. Its large capacity saves you time by holding up to 12 thermometers at once. Using ASL’s proven removable insert technology the B700 accepts a variety of temperature probe diameters and guarantees repeatable calibration performance to enable you to comply with your ISO9000 requirements. All B700s are tested over their full temperature range before dispatch and are supplied with a stability test certificate. B700 Brochure See the table below for a run-down of this product's features and capabilities.
For more information about this product contact ASL B140 Metal Block CalibratorThe B140 provides you with a convenient precision temperature source for the calibration of a wide range of industrial thermometers. Its range is ideally suited to the food processing industry covering the temperatures used for sterilisation, processing and storage. Using ASL’s proven removable insert technology the B140 accepts a variety of temperature probe diameters and guarantees repeatable calibration performance to enable you to comply with your ISO9000 requirements. All B140s are tested over their full temperature range before dispatch and are supplied with a stability test certificate. B140 Brochure
For more information about this product contact ASL B-CoolThe B-Cool forced air cooling probe allows rapid temperature reduction from 700°C to ambient in minutes rather than hours. With the B-cool system, up to eight calibration batch runs can be achieved each day without compromising calibrator accuracy. B-Cool Brochure For more information about this product contact ASL Calibration AccuracyThe accuracy of your calibration will depend on the sum of the accuracy of the reference thermometer with its indicator and the uncertainties associated with stability and uniformity of the block. Be cautious of claims for accuracy with no explanation, as it may be just another way to specify uniformity. The Independent Indicator option has probe data correction to improve accuracy and is supplied with, or without, probe and traceable calibration. For best results, use an external reference such as ASL's F100 or F200 series precision thermometers , offering a traceable system accuracy of up to ±0.025°C. Read more about Comparison Calibration UniformityUniformity is defined for the B series as the temperature difference between two probes in a two-hole insert. In the B700 a typical value is also shown for the fixed holes. For customised blocks, uniformity will depend on the design. "Gradient" or "homogeneity" are other terms used for describing uniformity. Further informationFind out more information about B series insert hole diameters
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 2 Gatton Park Business Centre Wells Place Redhill, Surrey RH1 3LG |